Air conditioner leaking water inside: how to find the cause and stop the drip
The short answer
An air conditioner in cooling mode pulls a surprising amount of water out of the air. Moisture condenses on the cold indoor coil, runs down into a shallow tray beneath it and flows away through a drain pipe, usually to a spot outside near the outdoor unit. On a humid day that can amount to several litres.
When water appears on the wall or drips from the front of the indoor unit, that drainage path has failed somewhere. Either the pipe is blocked and the tray is overflowing, or water is forming where the tray cannot catch it, typically because the coil froze and is now melting.
Water leaks tend to get worse, and water running down a wall near power points and into plaster does real damage. Turn the unit off when you first notice the drip and work through these checks before using it again.
Likely causes, most common first
Blocked condensate drain
DIY or professionalWater drips from the bottom edge or one end of the indoor unit after it has been cooling for a while. Little or nothing comes out of the drain pipe outside.
Dirty filters causing the coil to ice up
DIYWeak airflow, frost or ice visible behind the filters, and a rush of water when the unit is turned off and the ice melts.
Blocked or submerged drain outlet outside
DIYThe end of the drain pipe is plugged with mud, an insect nest or slime, is kinked, or sits in soil, mulch or standing water.
Indoor unit not level, or drain installed with poor fall
ProfessionalWater drips from the end of the unit opposite the drain. The unit visibly slopes, or it has leaked since it was installed.
Low refrigerant causing icing
ProfessionalThe coil ices up even with clean filters, the cooling is weak, and part of the coil is frosted while the rest is dry.
Failed condensate pump or cracked drain tray
ProfessionalThe unit is on an internal wall and uses a small pump that has gone quiet or noisy, or the leak continues with a clear drain and a clean coil.
Before you start
Safety first
- Turn the unit off at the remote, then switch off the isolator beside the outdoor unit, or the circuit breaker, before you open the indoor unit. Water and mains electricity are in the same enclosure.
- If water has run into a power point, light switch or light fitting, turn that circuit off at the switchboard and have an electrician check it before it is used again.
- Do not remove the indoor unit's outer casing or drain tray. On most models that involves working around live wiring and is a technician's job.
- Do not pour bleach, drain cleaner or boiling water into the unit. Harsh chemicals corrode the aluminium coil and can damage the tray and pipe.
- Use a stable step ladder, and mop up straight away. A wet timber or tiled floor under a ladder is a fall waiting to happen.
What you will need
- Towels and a bucket or tray
- Step ladder
- Torch
- Vacuum cleaner with a soft brush attachment
- Wet and dry vacuum (optional, for the drain outlet)
- Spirit level, or a level app on your phone
Step-by-step checks
Step 1: Turn the unit off and protect the area
Switch the unit off at the remote and at the isolator or breaker. Move furniture and anything electrical out from under the indoor unit, put towels down and place a bucket or tray under the drip.
Notice where the water is coming from. A drip from one end, or water running down the wall behind the unit, usually means an overflowing tray. Droplets being thrown out of the front louvres with the air point to a wet, dirty or iced-up coil.
Think about timing as well. A leak that only shows up on very humid days suggests a drain that is partly blocked and cannot keep up. A leak that appears just after the unit is switched off suggests melting ice.
Step 2: Check and wash the filters
Open the front panel and slide the mesh filters out. If they are grey with dust, they are restricting the airflow enough to let the coil temperature fall below freezing. Ice builds up on the fins, and when it melts the water lands outside the tray.
Vacuum the filters or wash them in lukewarm water with a little detergent, and leave them to dry in the shade. While they are out, shine a torch on the coil. Frost or ice confirms the diagnosis.
If there is ice, leave the unit off until it has melted completely, which can take a couple of hours. Keep the towels in place.
Tip: Dust that gets past dirty filters also feeds the slime that blocks drains. Clean filters deal with both causes at once.
Step 3: Find and check the drain outlet outside
The condensate drain is a small plastic pipe, flexible and ribbed or rigid, that normally leaves the wall with the insulated refrigerant pipes and ends near the outdoor unit, over a garden bed or at a drain. Follow the pipework down from the outdoor unit to find the open end.
Check the last section for anything blocking it. Mud wasps, spiders and ants like the opening, and slime can form a plug right at the end. Clear what you can see with your fingers or a short piece of wire, without pushing anything far up the pipe.
Make sure the end of the pipe is not buried in soil or mulch, sitting in a puddle, kinked, or running uphill at any point. The water moves by gravity alone, so a pipe that rises even slightly, or an end that is under water, will hold the water back.
Step 4: Draw the blockage out with a wet and dry vacuum
If you own a wet and dry vacuum, this is the most effective thing you can do from outside. Hold the vacuum hose over the end of the drain pipe, seal the gap with your hand or a damp rag, and run the vacuum for a minute or two.
A blocked drain often gives up a slug of grey or brown jelly followed by a rush of water. That jelly is a bacterial slime that grows in the dark, damp pipe, and it is the usual culprit.
Do not use an ordinary household vacuum, which is not built to take in water. Do not blow compressed air or run a garden hose up the pipe from outside either. Either one can push the blockage and dirty water back into the indoor unit and down your wall.
Step 5: Check that the indoor unit is level
Hold a spirit level or your phone along the top of the indoor unit. It should be level, or have the slight tilt toward the drain end that the installer set. A unit that slopes away from its drain outlet lets water pool at the wrong end of the tray and spill.
Look at how the unit sits on the wall. If it has dropped at one end or has pulled away from the wall, the mounting plate has moved. Do not try to lift or re-hang it yourself. The refrigerant pipes behind it are rigid copper and will kink or crack.
Step 6: Test it and watch the drain
With the filters dry and refitted, turn the power back on and run the unit in cool mode for 20 to 30 minutes. Keep an eye on the indoor unit and check the drain outlet outside.
On a humid day you should see a steady drip or a thin trickle from the pipe outside. That is the sign of a healthy drain. On a dry day there may be very little condensation, so no drip outside does not prove a blockage.
If the outlet stays dry and water appears indoors again, turn the unit off. The blockage is inside the tray or the pipe within the wall, and it needs to be flushed properly.
When to stop and call a repairer
- Water still leaks indoors after you have cleaned the filters and cleared the drain outlet.
- The coil ices up again with clean filters. That points to low refrigerant, which only a technician with a refrigerant handling licence may work on.
- The indoor unit is visibly out of level or has come away from the wall.
- The unit drains through a condensate pump that has stopped or become noisy.
- Water has reached a power point, switch or light fitting, or the plaster is stained or soft.
- The unit has leaked since it was installed. Contact the installer, because the fall on the drain is likely to be wrong.
Energy Safe Victoria recommends that gas heaters are serviced at least every two years by a qualified gasfitter, including a carbon monoxide test. A carbon monoxide alarm is a back-up, not a substitute. Air conditioner refrigerant work requires an ARCtick refrigerant handling licence.
What it costs
- Doing it yourself
- $0 if you have a wet and dry vacuum or can clear the outlet by hand.
- Professional repair
- About $200–$300 for a split-system service, which normally includes cleaning and flushing the drain. Call-out or diagnostic fees of $80–$200 are common and are often credited against the work. If icing is traced to a refrigerant leak, a regas with leak detection and repair is typically $400–$700.
Indicative ranges from 2026 Australian cost guides, not Melbourne quotes. Confirm that the drain flush is included in the service price before you book. See our Melbourne repair cost guide for more.
Repair or replace?
A water leak is almost never a reason to replace an air conditioner. The causes are blockages, dirt and installation details, not worn-out machinery, and a proper service usually cures it.
The exception is a leak caused by repeated icing on an old unit with a refrigerant leak in the indoor coil. Finding and repairing a coil leak can be costly, and on a system well past ten years old it is fair to compare the quote with the price of a new unit. Topping up the gas without fixing the leak is poor practice and the icing, and the dripping, will return.
If a recently installed unit leaks, go back to the installer or retailer before paying anyone else. Installation faults such as a drain with no fall should be put right by whoever did the work, and consumer guarantees under the Australian Consumer Law cover services as well as goods.
Not sure which way to go? Try the repair or replace calculator, and read your consumer rights before paying for a repair on something that failed early.
Common questions
Is it safe to keep using an air conditioner that is leaking water?
It is better not to. The water can damage plaster, flooring and furniture, and it may reach wiring inside the unit or in the wall. Turn it off, find the cause, and use it again once it drains properly.
Why does my air conditioner only leak on humid days?
Humid air carries more moisture, so the unit produces far more condensate. A partly blocked drain can cope with a trickle on a dry day and overflow when the volume rises. The drain needs clearing.
Water drips from a pipe outside when the air conditioner runs. Is that a leak?
No. That is the condensate drain working as intended. A steady drip outside in cooling mode is a good sign. It is water inside the house that indicates a problem.
Can I pour vinegar or bleach into the unit to clear the drain?
We would not. Bleach and other strong chemicals can corrode the aluminium coil, and pouring any liquid into the indoor unit risks wetting the electronics. Clearing the outlet and drawing the blockage out from the outside end is the safer approach. A technician can flush the tray and pipe correctly.
How do I stop the drain from blocking again?
Keep the filters clean so less dust reaches the tray, keep the outlet end clear of soil and insect nests, and have the system serviced periodically. A service includes cleaning the tray and flushing the drain line.
Melbourne repairers for air conditioning & heating
Independent businesses that list this kind of work. Listings are free and are not endorsements. Always confirm prices, licences and availability directly.
RapidFix Solutions
Mobile service113 East St, Hadfield VIC 3046
On-site repairs of ducted gas and reverse-cycle heating, split system, ducted and evaporative cooling, domestic fridges and freezers, washing machines, dryers, dishwashers, ovens and cooktops.
Services Glenroy, Coburg, Brunswick, Pascoe Vale, Essendon and other suburbs.
Dynamic Heating and Cooling
Mobile serviceMobile · West
Services and repairs split system and ducted air conditioning and gas ducted heating, including carbon monoxide testing, for brands including Daikin, Mitsubishi, Fujitsu, ActronAir, Panasonic, Braemar, Brivis and Vulcan.
Services inner and north-western suburbs such as Abbotsford, Brunswick, Footscray, Sunshine and Williamstown.
Advance Heating and Cooling
Shopfront & mobileShop 3, 296 Ballarat Rd, Braybrook VIC 3019
Services and repairs gas, reverse-cycle and electric ducted heating, split systems, evaporative cooling and gas wall furnaces, naming Brivis, Braemar, Bonaire and Rinnai.
Plum Trade Services
Mobile serviceUnit 4, 22-30 Wallace Ave, Point Cook VIC
Repairs and services split system, multi-split, ducted reverse-cycle and evaporative air conditioning and ducted gas heating, for brands including Brivis, Braemar, Bonaire, Vulcan, Daikin, Fujitsu, Mitsubishi and Panasonic.
Services the western suburbs.
This guide is general information, not professional advice for your specific appliance or situation. Follow your manufacturer's manual where it differs, and read our disclaimer. Spotted an error? Tell us.
More heating & cooling guides
Split system not cooling (or heating) properly: checks you can do yourself
Split system blowing weak or lukewarm air? Check the mode, filters, outdoor unit and breaker first, and learn the signs of low refrigerant or an iced coil.
Ducted gas heater not working: safe checks, and when to call a gasfitter
Ducted heating not starting or blowing cold air? Check the thermostat, power, return-air filter and vents, and know the carbon monoxide warning signs.